Back to top

Specification

  • कवरेज एरिया
  • Custom Sizes Available
  • माउंटिंग टाइप
  • Floor Mounted
  • इंस्टालेशन टाइप
  • Floor Mounting/Laid On Floor
  • काम करने का तापमान
  • -10C to +55C
  • फायर क्लास
  • Class A
  • शेप
  • Rectangular/Sheet/Roll
  • कंट्रोल टाइप
  • Manual
  • वोल्टेज
  • 3.3 kV, 11 kV & 33 kV (Tested as per IS 15652:2006)
  • कोटिंग का प्रकार
  • Smooth or Chequered
  • विशेषताएँ
  • High Dielectric Strength, Anti-Skid, Oil & Acid Resistant, Moisture Proof, Flame Retardant
  • टेक्नोलॉजी
  • Elastomeric Compound
  • एप्लीकेशन
  • Electrical Insulation for Safety in High Voltage Areas
  • व्यास
  • Customizable
  • प्रेशर
  • Atmospheric
  • Water Absorption
  • < 0.5%
  • Length
  • 1 Meter up to 10 Meter or customized
  • Thickness
  • 2 mm, 2.5 mm, 3 mm (as per required standard)
  • Width
  • 1 Meter / 1.2 Meter / 1.5 Meter or customized
  • Elongation at Break
  • > 250%
  • Surface Finish
  • Smooth/Antiskid/Chequered
  • Tensile Strength
  • > 15 N/mm2
  • Standards
  • IS 15652:2006, IEC 61111
  • Color
  • Black, Blue, Red, Green (varies as per supply)
  • Breakdown Voltage
  • Up to 65 kV (Depending on thickness)
  • Material
  • PVC Elastomer/Polymeric Compound
 

Trade Information

  • Minimum Order Quantity
  • 5 टुकड़ाs
  • आपूर्ति की क्षमता
  • प्रति महीने
  • डिलीवरी का समय
  • दिन
 

About



Explore top-notch electrical insulating mats engineered for champion-level safety in high-voltage areas. Personalise your solution with imposing thickness options of 2 mm, 2.5 mm, or 3 mm, all manufactured to IS 15652:2006 and IEC 61111 standards. Choose from striking colors-black, blue, red, or green-crafted from robust PVC elastomer/polymeric compounds. With a high dielectric strength and anti-skid surface, these mats are ideal for ending soon hazards in electrical environments. Available in customized shapes and sizes, they deliver unmatched moisture-proof, flame-retardant performance for assured protection.

Specific & General Uses for Electrical Insulating Mats

Electrical insulating mats are widely used for both specific and general electrical insulation, particularly as a reliable safety measure in high-voltage switchyards and substations. These mats are used as flooring beneath electrical panels, machinery, or control rooms to protect users from electric shocks. The main advantage lies in their high dielectric strength, oil and acid resistance, and moisture-proof qualities, ensuring workplace safety and system integrity.


Domestic Market Reach & Supply Adaptability

Serving a vast domestic market and reaching export destinations, our electrical insulating mats are supplied across India with high adaptability to user needs. With a strong supply capability, we provide both standard and custom-sized mats, ensuring timely and tailored service. Sample policies reflect our commitment to customer satisfaction, enabling clients to assess quality before bulk orders. We cater to wholesalers, retailers, traders, and service providers alike.


FAQ's of electrical insulating mat:


Q: How do electrical insulating mats enhance safety in high-voltage areas?

A: Electrical insulating mats act as protective barriers against electric shocks in high-voltage environments, ensuring safe operation by preventing electrical currents from passing through the floor to the user.

Q: What standards do your insulating mats comply with?

A: Our insulating mats meet IS 15652:2006 and IEC 61111 standards, ensuring they meet stringent safety, durability, and performance criteria essential for electrical insulation applications.

Q: When should an electrical insulating mat be replaced?

A: Mats should be inspected regularly and replaced if there are visible signs of wear, cuts, chemical damage, loss of anti-skid properties, or if they fail electrical resistance testing, to maintain optimal safety.

Q: Where are these mats typically installed?

A: These mats are commonly installed in substations, switchyards, transformer rooms, control panels, generator rooms, and other high-voltage electrical zones to safeguard operators and technicians.

Q: What are the benefits of choosing a mat with flame-retardant and anti-skid features?

A: Flame-retardant and anti-skid features enhance workplace safety by reducing fire hazards and providing stable footing in environments where slips or electrical fires pose risks.

Price 1000 आईएनआर/ टुकड़ा

  • Minimum Order Quantity
  • Supply Ability
  • Delivery Time
Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
मोबाइल number

Email

अधिक Products in फायर अलार्म Category

inline foam inductor

न्यूनतम आदेश मात्रा : 5

कवरेज एरिया : Dependent on foam nozzle and type

मूल्य की इकाई : टुकड़ा/टुकड़ाs

शेप : Cylindrical

काम करने का तापमान : 5C to +49C

इंस्टालेशन टाइप : Inline, between hose line and nozzle

Honywell Raeguard 2 PID

न्यूनतम आदेश मात्रा : 20

कवरेज एरिया : Depends on installation and site layout

मूल्य की इकाई : टुकड़ा/टुकड़ाs

शेप : Rectangular with front display

काम करने का तापमान : 40C to +65C (40F to +149F)

इंस्टालेशन टाइप : Wall or pipe mount

electrical safety kit

न्यूनतम आदेश मात्रा : 5

कवरेज एरिया : Depends on kit deployment; typically covers one operator

मूल्य की इकाई : Kit/Kits

शेप : Rectangular carry case

काम करने का तापमान : 10C to 55C

इंस्टालेशन टाइप : Portable kit, not fixed installation

Fire Blankets

न्यूनतम आदेश मात्रा : 20

कवरेज एरिया : Standard Size 1.2m x 1.2m (custom sizes available)

मूल्य की इकाई : टुकड़ा/टुकड़ाs

शेप : Rectangular

काम करने का तापमान : Withstands up to 550C 900C

इंस्टालेशन टाइप : WallMounted Pouch or Box